For the counting of dust particles with a particle size greater than or equal to 0.5μm, the light scattering particle counting method should be used, and the filter microscope counting method can also be used.


Product Detail

Product Tags

Clean room (area) air cleanliness level table

1. The air cleanliness of the clean room should be tested as follows

(1) Empty state, static test

Empty state test: The clean room has been completed, the purified air conditioning system is in normal operation, and the test is carried out without process equipment and production personnel in the room.

Static test: The clean room purification air conditioning system is in normal operation, the process equipment has been installed, and the test is carried out without production personnel in the room.

(Two) dynamic test

The clean room has been tested under normal production conditions.

The detection of air volume, wind speed, positive pressure, temperature, humidity, and noise in the clean room can be carried out in accordance with the relevant regulations of general use and air conditioning.

Clean room (area) air cleanliness level table

Cleanliness level Maximum allowable number of dust particles/m3≥0.5μmNumber of dust particles ≥5μmNumber of dust particles Maximum allowable number of microorganisms

Planktonic bacteria/m3

Settling bacteria/dish
100class 3,500 0 5 1
10,000class 350000 2000 100 3
100000class 3500000 20000 500 10
300000class 10500000 60000 1000 15